Thứ Ba, 15 tháng 7, 2014

Điện cực ứng dụng trong công nghiệp


Mọi thông tin xin liên hệ:

NGUYỄN HOÀNG LONG (Mr.)
Phó Giám đốc
H/P    : 0932 664422
Tel     : (08) 66 570 570
Fax    : (08) 35 951 053
Mail  : sales@vietnguyenco.vn
            www.thietbithinghiem.org
            www.bomlaymaukhi.com
            www.thietbidokhidoc.com
            www.thietbiquantracmoitruong.com
            www.thietbiphantichmoitruong.vn
            www.noithatphongthinghiem.com.vn
            www.noithatphongthinghiem.vn
            www.labfurniture.vn


Điện cực ứng dụng trong công nghiệp
Reference at: http://www.consort.be/
Supplied with S8 plug head

SP11Y

  • Rugged easy to clean Tuff-Tip®, pH
  • Epoxy body
  • 0...14 pH, 0...100°C
  • Double junction, sealed
  • 110xØ12 mm

SP23Y
  • High temperature, pH
  • Glass body
  • 0...14 pH, 5...110°C
  • Double junction, sealed
  • 110xØ12 mm

SP50Y
  • General purpose, ORP
  • Epoxy bodyp
  • 0...±2000 mV, 0...80°C
  • Single junction, sealed
  • 110xØ12 mm

SP61Y
  • General purpose, ORP
  • Glass body
  • 0...±2000 mV, 0...100°C
  • Single junction, sealed
  • 110xØ12 mm

SK10Y
  • General purpose, conductivity
  • Epoxy body
  • 1 cm-1, 0...80°C
  • Dual graphite plates
  • 110xØ12 mm

SK20Y
  • General purpose, conductivity
  • Glass body
  • 1 cm-1, 0...110°C
  • Dual platinum rings
  • 110xØ12 mm

SK22Y
  • Low conductivities
  • Glass body
  • 0.1 cm-1, 0...110°C
  • Dual platinum plates
  • 110xØ12 mm

SK23Y
  • High conductivities
  • Glass body
  • 10 cm-1, 0...110°C
  • Dual platinum rings
  • 110xØ12 mm

ST21Y
  • General purpose, ATC/temperature
  • Glass body
  • -30...+130°C
  • Pt1000
  • 110xØ12 mm

SZ12T
  • Dissolved oxygen, galvanic type + ATC (Pt1000)
  • Delrin body
  • 0...60 mg/l
  • 0...50°C
  • With 15 m cable + 2 BNC plugs
  • 110xØ12 mm
SZ02K
  • set of 3 membranes + electrolyte
1.      Order Info:
Item
Code
Description
01
SC01B
S7/S8 cable, 1 m, with BNC plug
02
SC03B
S7/S8 cable, 3 m, with BNC plug
03
SC06B
S7/S8 cable, 6 m, with BNC plug
04
SC15B
S7/S8 cable, 15 m, with BNC plug
05
SC30B
S7/S8 cable, 30 m, with BNC plug

Phần mềm thu nhận dữ liệu cho điều khiển trong công nghiệp


Mọi thông tin xin liên hệ:

NGUYỄN HOÀNG LONG (Mr.)
Phó Giám đốc
H/P    : 0932 664422
Tel     : (08) 66 570 570
Fax    : (08) 35 951 053
Mail  : sales@vietnguyenco.vn
            www.thietbithinghiem.org
            www.bomlaymaukhi.com
            www.thietbidokhidoc.com
            www.thietbiquantracmoitruong.com
            www.thietbiphantichmoitruong.vn
            www.noithatphongthinghiem.com.vn
            www.noithatphongthinghiem.vn
            www.labfurniture.vn


Phần mềm thu nhận dữ liệu cho điều khiển trong công nghiệp
Model: DIS-2
Tham khảo tại: http://www.consort.be/

DIS-2

1.      Overview:
Data acquisition:
-          This software package is specially designed to collect, store and manage data from the fol-lowing controllers when equipped with an RS485 interface:
§  R3620, R3630: It can also be used with the following previous models or versions when equipped with an RS485 interface:
§  R305, R315, R335: Runs under Windows™ 2000 or higher.
-          All measurements of all instruments are processed at the same time, each in its own win-dow.
-          Data is collected on-line at a programmable interval determined by the program (1 s ... 24 h).
Starting:
-          By using a program-key, the data-logging will start automatically after opening the pro-gram.
-          Data-logging can be stopped or continued at any moment.
-          Data, which is stored in the internal memory of the connected instrument, can also be read and processed.
Table:
-          Data is always stored in a table.
-          Comments can be added to each line in a special information column.
Files:
-          All data is saved in a user defined file. Just open the file to view, process or print the stored data.
-          The incoming data from the RS232 or Ethernet port can be stored immediately in a file.
-          All measurements are saved in CVS format which is easily transferred into spreadsheets.
Graphs:
-          Graphs are generated using automatic or user defined settings.
-          The number of visible values can be changed at any time.
-          Programmable alarm limits for each graph allow to print a report indicating when limits have
been exceeded.
-          Shows statistics about minima, maxima and averages.
Communication port:
-          COM1 to COM9 can be used to connect up to
nine series of max. 31 instruments.
-          Baud rate: 300..9600 b/s.
Terminal:
-          The terminal window shows exactly how data
is received through the RS232 or Ethernet port.
-          It enables the user to check for possible errors
in the data transmission.
Settings:
-          Languages: English, Dutch or French.
-          The style of each window can be set up sepa-rately.
-          Choose fonts, colours etc...
-          Documented printouts will show:
§  file name.
§  date and time.
§  name of the operator.
§  name of the company.
§  name of the division.
§  optional notes by the operator.
-          All settings are stored in a configuration file
and automatically recalled when opening the
program.
Functions:
-          All functions are accessible through the menu.
-          Only valid options appear in the menu to eliminate set-up errors.
-          Special buttons, icons and short-keys allow the user to easily access the most useful func-tions.
-          The contents of each window can be trans-ferred to other programs by using a copy func-tion.
-          Tile or cascade the windows and arrange the icons fully automatically or rearrange them
manually.

2.      Order Info:

Item
Code
Description
02
A2002
Data acquisition software DIS-2 + RS232/RS485 adaptor (optional)
03
A2003
Data acquisition software DIS-2 + RS485/Ethernet adaptor (optional)

R3610 • R3620 • R3624 - Bộ điều khiển đa thông số


Mọi thông tin xin liên hệ:

NGUYỄN HOÀNG LONG (Mr.)
Phó Giám đốc
H/P    : 0932 664422
Tel     : (08) 66 570 570
Fax    : (08) 35 951 053
Mail  : sales@vietnguyenco.vn
            www.thietbithinghiem.org
            www.bomlaymaukhi.com
            www.thietbidokhidoc.com
            www.thietbiquantracmoitruong.com
            www.thietbiphantichmoitruong.vn
            www.noithatphongthinghiem.com.vn
            www.noithatphongthinghiem.vn
            www.labfurniture.vn


Bộ điều khiển đa thông số
Model: R3610 • R3620 • R3624
Tham khảo tại: http://www.consort.be/

1.      Overview:
Control:
-          Two independent channels allow to control any two functions simultaneously, each with its own temperature compensation.
-          On/off or proportional control.
-          Four solid state relays programmable for high/low level control, wash program or alarm functions.
-          Allows to stop temporarily the control (relays off) without holding the measurements.
-          Wash program for an automatic periodical cleaning of the electrodes.
-          A programmable alarm function prevents the overdosing of chemicals in the process liquid. Each time a pre-set level is exceeded the corresponding elay is closed and the alarm timer starts to count down. When this level is still exceeded after count down of the timer all relays will be opened and an alarm be given. The system should then be checked thoroughly for e.g. broken electrodes, interrupted cables, empty vessels, etc...
pH:
-          Multi-point (1...5) calibration for more linearity.
-          Selectable resolution from 0.001 pH to 0.1 pH.
-          Automatic calibration with any of eleven pre-programmed and five user specified pH buffers.Create your own buffer/temperature tables!
mV:
-          Features mV calibration for accurate ORP measurements.
-          Selectable resolution from 0.1 mV to 1 mV.
Ion (R362x only):
-          Direct concentration measurement.
-          Multi-point (2...5) calibration and an additional blank correction for measuring low concentrations.
Conductivity:
-          Multi-point (1...3) calibration for more linearity.
-          The 4-pole design reduces considerably the problems of polarisation and fouling. By utilising four electrodes, no current flows through the measuring circuit. The AC-current is only applied to the outer pair of rings allow-ing the inner pair of electrodes to measure the voltage without any polarisation effects. A 4-pole electrode permits to measure with the highest degree of accuracy and linearity (R3624 only).
-          An electrode with a typical cell constant of 1 cm-1permits to measure from 0.01 µS/cm to 200 mS/cm in five ranges.
-          An electrode with a typical cell constant of 0.1 cm-1permits to measure from 0.001 µS/cm to 20 mS/cm in five ranges.
-          An electrode with a typical cell constant of 10 cm-1permits to measure from 0.1 µS/cm to 2000 mS/cm in five ranges.
-          Automatically selects correct range and frequency.
-          Selectable reference temperature: 20° or 25°C.
-          Automatic calibration with any of three preprogrammed and three user specified standard solutions.Create your own standard/temp. tables!
-          Accurate low conductivity measurements by eliminating the capacitive component of the electrode and its cable (avoid the use of long cables!).
Dissolved oxygen:
-          Operates with a galvanic oxygen electrode requiring no polarisa-tion time and no zero calibration.
-          Selectable resolution from 0.01 mg/l (0.1%) to 0.1 mg/l (1%).
-          Rapid air calibration.
-          Manual salinity compensation 0-40.
-          Automatic air pressure compensation 600-1300 hPa.
Temperature:
-          Reads temperatures with 0.1°C resolution.
-          Manual or automatic temperature compensation.
-          Calibrates temperature probe for quality measure-ments.
Inputs:
-          Two inputs for pH, mV, Ion, conductivity or dissolved oxygen.
-          Two inputs for temperature.
-          R3624:one DIN-8 connector for 4-pole conductivity electrodes with built-in Pt1000.
Outputs (R362x only):
-          Two programmable 4-20 mA analogue outputs, for con-nection to a proportional pump, a PLC or an industrial recorder.
-          RS485 interface permits to connect up to 31 contollers in a network system with a computer.
Display:
-          A large bright LCD screen with white backlight enables to view all channels simultaneously.
-          The interactive LCD screen provides step by step instruc-tions in the language of your choice (English, Dutch, French, German).
-          Real-time clock displays time and date.
-          Shows a GLP report on the LCD screen.
Connections:
-          All connections, except for the inputs, can be done through internal screw terminals.
Cabinet:
-          Robust dust and splash-proof cabinet for wall mounting.
Data-logging (R362x only):
-          Stores up to 12000 values including temperature, time and date at a programmable interval.
-          An optional powerful data acquisition software for PC + RS485/RS232 or RS485/Ethernet adaptor is available separately.
-          Can be connected in a network system with up to 31 controllers and a computer.
-          Two-way communication with any computer using RS485.
-          Programmable identification number.
-          Stores minimum/maximum readings for each channel.
Special features:
-          Three year warranty.
-          No electrical interference between electrodes in the same solution.
-          Galvanic input/output isolation eliminates ground loop interferences.
-          A first special timer can start a wash program for an automatic periodical cleaning of the electrodes.
-          A second special timer can give alarm to interrupt the process control in case of a pump overfeed or an elec-trode failure.
-          Password protection prevents any unauthorised modifi-cation of the instrument's settings.
GLP:
-          All procedures for a "Good Laboratory Practice" are on board.
Pre-programmed standards:
-          pH buffers: 1.68, 2.00, 4.00, 4.01, 6.87, 7.00, 9.18, 9.21, 10.01, 12.00, 12.45 (at 25°C).
-          Conductivity: 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm (at 25°C)

2.      Technical Data:
pH:
-           Range: -2...+16 pH
-          Resolution: 0.001 pH
-          Accuracy: 0.1% ± 1 digit
-          Calibration: 1...5 points
-          Buffers: 11 pre-programmed + 5 user specified
-          Temperature compensation: -5...+105°C
-          ISO-pH: 6...8 pH
-          Slope: 80...120%
mV:
-           Range: ±2000 mV
-          Resolution: 0.1 mV
-          Accuracy: 0.1% ± 1 digit
-          Calibration: 1 point
ION (R362x only):
-          Range: 0.01 ng/l...100 g/l
-          Resolution: 3 digits
-          Accuracy: 0.5% ± 1 digit
-          Calibration: 2...5 points + blank
CONDUCTIVITY:
-           Range (cc dependent): 0...2000 mS/cm
-          Resolution (cc dependent): 0.001 µS/cm
-          Accuracy: 0.5% f.s. of range
-          Calibration: 1...3 points
-          Standards: 3 pre-programmed + 3 user specified
-          Cell constant (cc) 0.1/1/10 cm-1±30%
-          Temperature compensation: -5...+105°C
-          Reference temperature: 20° or 25°C
-          Temperature coefficient natural waters (EN27888)
-          Capacitive compensation
DISSOLVED OXYGEN:
-          Range: 0...60 mg/l (0...600%)
-          Resolution: 0.01 mg/l (0.1%)
-          Accuracy:  1% ± 1 digit
-          Calibration: 1 point
-          Temperature compensation: 0...50°C
-          Salinity compensation: 0...40
-          Air pressure compensation: 600...1300 hPa
TEMPERATURE:
-           Range: -5...+105°C
-          Resolution: 0.1°C
-          Accuracy: 0.1°C
-          Calibration: 1 point
AIR PRESSURE:
-          Range: 600...1300 hPa
-          Calibration: 1 point
CHANNELS:
-           Measurement: 2
-          Temperature: 2
INPUTS:
-           Measurement: 2 BNC, 1012
-          Temperature: 2 BNC, for Pt1000
-          Four-pole conductivity cell 1 DIN-8 (R3624 only)
CALIBRATION:
-          Reminder: 0...999 h
-          GLP
CONTROL:
-           On/Off
-          Proportional
-          Wash program
-          Alarm timer
DISPLAY:
-           LCD: 240x64 pixels
-          White backlight
-          Real time clock
ANALOG OUTPUTS (R362x only):
-           Two outputs: 4...20 mA, max. 300 Ω load
COMMUNICATION:
-           RS485, baud rate 300...19200 b/s
-          Computer via RS485/RS232 interface
DATA-LOGGING (R362x only):
-           Data sets 12000 + °C/date/time
-          Modes all
-          Interval: 1 s...4 h
RELAY OUTPUT:
-           Four relays 4 solid state
-          Voltage 12...250 VAC/ min. 1 mA/ max. 1 A
SECURITY:
-           Identification number
-          Password protection
AMBIENT CONDITIONS:
-          Temperature: 0...40°C
-          Humidity: 0...95%, non condensing
POWER SUPPLY: Mains 210...250 VAC, 50/60 Hz
DIMENSIONS: WxDxH 28x17x6 cm
WEIGHT: Meter 1.3 kg

3.      Order Info:

Item
Code
Description
01
R3610
Controller for pH/mV/ion/conductivity/dissolved oxygen
02
R3620
Controller for pH/mV/ion/conductivity/dissolved oxygen
03
R3624
Controller for pH/mV/ion/conductivity/dissolved oxygen
03
A2002
Data acquisition software DIS-2 + RS232/RS485 adaptor (optional)
04
A2003
Data acquisition software DIS-2 + RS485/Ethernet adaptor (optional)